QuantiFERON(R)-TB Gold Plus (Client Incubated)
Test Code: 182893
Performing Lab: LabCorp
CPT Code: 86480 001
Synonym
Interferon-gamma Release Assay (IGRA) for Mycobacterium tuberculosis; QFT-Plus
Specimen Type
Whole blood
Specimen Container
The QuantiFERON(R)-TB Gold Plus collection kit contains the instructions for the collection and handling of (one each): (1) gray-top (with white ring), uncoated (nil); (2) green cap with white ring, TB1 tube; (3) yellow cap with white ring, TB2 tube; (4) purple top with white ring, mitogen-coated. A high altitude kit is also available for locations between 3350 and 6150 feet; a cap with a yellow ring differentiates the tubes.
Volume
1 mL x four tubes in QuantiFERON-TB Gold Plus kit
Minimum Volume
1 mL x four tubes in QuantiFERON-TB Gold Plus kit
Specimen Handling
Blood collections tubes should be at room temperature at the time of collection. Refer to collection instructions included with draw kit. Special specimen collection kit contains four gel-barrier tubes as noted above. All four tubes are required for a single test result. Each tube is designed to draw only 1 mL and fill time may be longer than other blood collection tubes. Because of the limited vacuum in these tubes, use a needle and holder (not a butterfly) to collect QuantiFERON(R)specimens. If a butterfly is required, first collect other required tubes or use another Vacutainer (R) tube to purge the butterfly line of air and then proceed with drawing the QuantiFERON tubes. Fill tubes to the black fill line on the tube. If tubes are underfilled or overfilled (see kit insert), immediately collect a replacement tube. Following proper fill, label the tubes appropriately and shake tubes 10 times firmly enough to ensure the entire surface of the tube is coated with blood cells to solubilize the antigen on the tube walls. After shaking, the volume may fall below the fill line. Do NOT centrifuge or refrigerate specimens. Return each of the four properly filled, labeled, and shaken tubes to the box labeled "QFT kit." Seal the top by removing tape from the adhesive.
Unacceptable Conditions
Grossly hemolyzed, icteric, or lipemic samples; expired collection tubes; Specimen centrifuged, refrigerated, or frozen; specimen more than 94 hours old on receipt by lab; receipt of three tube collection kit. Under-filled or over-filled tubes; tubes that do not yield sufficient plasma for testing.
Temperature
1. Maintain specimen at room temperature prior to incubation at 37 degrees C. Stability: Kit MUST be incubated within 16 hours of collection. 2. After incubation, maintain specimen at room temperature (17 degrees C to 27 degrees C). Do NOT centrifuge refrigerate, or ship tubes on ice.
Methodology
Whole blood interferon-gamma test measuring responses to CD4+ and CD8+ T cell antigens
| Result Code | Result Name | LOINC |
|---|---|---|
| 182885 | QuantiFERON Criteria | 8251-1 |
| 182886 | QuantiFERON TB1 Ag Value | 64084-7 |
| 182887 | QuantiFERON TB2 Ag Value | 88517-8 |
| 182891 | QuantiFERON Nil Value | 71776-9 |
| 182892 | QuantiFERON Mitogen Value | 71774-4 |
| 182894 | QuantiFERON-TB Gold Plus | 71773-6 |
Select Print Details