ADAMTS13 Antibody
Test Code: 117915
Performing Lab: LabCorp
CPT Code: 83520 001
Specimen Type
Plasma, FROZEN
Specimen Container
Blue-top (sodium citrate) tube
Volume
0.5 mL
Specimen Handling
Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate.[1] Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio.[2,3] The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples.[4,5] When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue- top tube. Serum gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge and carefully remove the plasma using a plastic transfer pipette, being careful not to disturb the cells. Transfer the plasma into a LabCorp PP transpak frozen purple tube with screw cap (LabCorp ID 49482). The specimen should be frozen immediately and maintained frozen until tested. To avoid delays in turnaroud time when requesting multiple tests on frozen samples, PLEASE SUBMIT SEPARATE FROZEN SPECIMENS FOR EACT TEST REQUESTED.
Unacceptable Conditions
Non-frozen sample received, non-citrate plasma received; sample left on cells.
Temperature
FREEZE
Methodology
Enzyme-linked immunosorbent assay (ELISA) using microtiter plates coated with a recombinant form of ADAMTS13 protease.
Stability
Room Temperature: Unstable
Refrigerated: Unstable
Frozen: 14 days
Refrigerated: Unstable
Frozen: 14 days
| Result Code | Result Name | LOINC |
|---|---|---|
| 117916 | ADAMTS13 Antibody | 40824-5 |
Select Print Details